Math & Conversion — Client-side
| Quantity | Value |
|---|
A divider is only ideal while the load draws nothing. The output impedance is R1∥R2, so once RL comes within about 100× of R2 the parallel pair is dominated by the load and Vout sags far below Vs·R2/(R1+R2). Buffer the output (op-amp follower) or use a much smaller divider impedance.